Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IBPSA_latest_IBPSA.ThermalZones.ISO13790.Examples.HeatingCoolingHVAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IBPSA with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IBPSA.ThermalZones.ISO13790.Examples.HeatingCoolingHVAC,fileNamePrefix="IBPSA_latest_IBPSA_ThermalZones_ISO13790_Examples_HeatingCoolingHVAC",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(IBPSA.ThermalZones.ISO13790.Examples.HeatingCoolingHVAC,fileNamePrefix="IBPSA_latest_IBPSA_ThermalZones_ISO13790_Examples_HeatingCoolingHVAC",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001157/0.001157, allocations: 191.1 kB / 7.804 MB, free: 2.496 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo): time 0.4799/0.4799, allocations: 90.85 MB / 99.07 MB, free: 14.92 MB / 90.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.331/1.331, allocations: 221.4 MB / 342.7 MB, free: 5.121 MB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009559/0.0009559, allocations: 85.88 kB / 415.5 MB, free: 9.812 MB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 0.1536/0.1546, allocations: 78.45 MB / 493.9 MB, free: 11.45 MB / 394.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3422/0.4968, allocations: 72.31 MB / 0.553 GB, free: 44.77 MB / 410.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 3.87/4.367, allocations: 1.901 GB / 2.454 GB, free: 156.2 MB / 0.6042 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002544/4.367, allocations: 87.95 kB / 2.455 GB, free: 156.1 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/Zone5R1C/Zone.mo:186:3-187:63:writable] Warning: connect(heaPorSur, heaPorSur) connects the same connector instance! The connect equation will be ignored. Error: Too many equations, over-determined system. The model has 1646 equation(s) and 1622 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1086 (size: 1) zonHVAC.win.HDifTil[1].weaBus.HDifHor = zonHVAC.win.HDirTil[3].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1085 (size: 1): zonHVAC.win.HDifTil[1].weaBus.HDifHor = zonHVAC.win.HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1087 (size: 1) zonHVAC.win.HDifTil[1].weaBus.HDifHor = zonHVAC.win.HDirTil[4].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1085 (size: 1): zonHVAC.win.HDifTil[1].weaBus.HDifHor = zonHVAC.win.HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1102 (size: 1) zonHVAC.win.HDifTil[1].weaBus.HGloHor = zonHVAC.win.HDirTil[3].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1101 (size: 1): zonHVAC.win.HDifTil[1].weaBus.HGloHor = zonHVAC.win.HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1103 (size: 1) zonHVAC.win.HDifTil[1].weaBus.HGloHor = zonHVAC.win.HDirTil[4].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1101 (size: 1): zonHVAC.win.HDifTil[1].weaBus.HGloHor = zonHVAC.win.HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1110 (size: 1) zonHVAC.win.HDifTil[1].weaBus.alt = zonHVAC.win.HDirTil[3].weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 1109 (size: 1): zonHVAC.win.HDifTil[1].weaBus.alt = zonHVAC.win.HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1111 (size: 1) zonHVAC.win.HDifTil[1].weaBus.alt = zonHVAC.win.HDirTil[4].weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 1109 (size: 1): zonHVAC.win.HDifTil[1].weaBus.alt = zonHVAC.win.HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1142 (size: 1) zonHVAC.win.HDifTil[1].weaBus.solZen = zonHVAC.win.HDirTil[3].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1141 (size: 1): zonHVAC.win.HDifTil[1].weaBus.solZen = zonHVAC.win.HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/GlazedElements.mo:41:3-44:22:writable] Warning: Equation 1143 (size: 1) zonHVAC.win.HDifTil[1].weaBus.solZen = zonHVAC.win.HDirTil[4].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1141 (size: 1): zonHVAC.win.HDifTil[1].weaBus.solZen = zonHVAC.win.HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1448 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.HDifHor = zonHVAC.opa.HDirTil[3].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1447 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.HDifHor = zonHVAC.opa.HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1449 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.HDifHor = zonHVAC.opa.HDirTil[4].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1447 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.HDifHor = zonHVAC.opa.HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1458 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.HGloHor = zonHVAC.opa.HDirTil[3].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1457 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.HGloHor = zonHVAC.opa.HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1459 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.HGloHor = zonHVAC.opa.HDirTil[4].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1457 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.HGloHor = zonHVAC.opa.HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1468 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.alt = zonHVAC.opa.HDirTil[3].weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 1467 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.alt = zonHVAC.opa.HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1469 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.alt = zonHVAC.opa.HDirTil[4].weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 1467 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.alt = zonHVAC.opa.HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1478 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.solZen = zonHVAC.opa.HDirTil[3].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1477 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.solZen = zonHVAC.opa.HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/BaseClasses/OpaqueElements.mo:68:3-71:22:writable] Warning: Equation 1479 (size: 1) zonHVAC.opa.HDifTil[1].weaBus.solZen = zonHVAC.opa.HDirTil[4].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.opa.HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1477 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.solZen = zonHVAC.opa.HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/Zone5R1C/Zone.mo:196:3-203:48:writable] Warning: Equation 1520 (size: 1) zonHVAC.opa.weaBus.HDifHor = zonHVAC.win.weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.weaBus.HDifHor, zonHVAC.opa.weaBus.HDifHor Equations used to solve those variables: Equation 1088 (size: 1): zonHVAC.win.HDifTil[1].weaBus.HDifHor = zonHVAC.win.weaBus.HDifHor Equation 1451 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.HDifHor = zonHVAC.opa.weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/Zone5R1C/Zone.mo:196:3-203:48:writable] Warning: Equation 1524 (size: 1) zonHVAC.opa.weaBus.HGloHor = zonHVAC.win.weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.weaBus.HGloHor, zonHVAC.opa.weaBus.HGloHor Equations used to solve those variables: Equation 1104 (size: 1): zonHVAC.win.HDifTil[1].weaBus.HGloHor = zonHVAC.win.weaBus.HGloHor Equation 1461 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.HGloHor = zonHVAC.opa.weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/Zone5R1C/Zone.mo:196:3-203:48:writable] Warning: Equation 1526 (size: 1) zonHVAC.opa.weaBus.alt = zonHVAC.win.weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.weaBus.alt, zonHVAC.opa.weaBus.alt Equations used to solve those variables: Equation 1112 (size: 1): zonHVAC.win.HDifTil[1].weaBus.alt = zonHVAC.win.weaBus.alt Equation 1471 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.alt = zonHVAC.opa.weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/Zone5R1C/Zone.mo:196:3-203:48:writable] Warning: Equation 1534 (size: 1) zonHVAC.opa.weaBus.solZen = zonHVAC.win.weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: zonHVAC.win.weaBus.solZen, zonHVAC.opa.weaBus.solZen Equations used to solve those variables: Equation 1144 (size: 1): zonHVAC.win.HDifTil[1].weaBus.solZen = zonHVAC.win.weaBus.solZen Equation 1481 (size: 1): zonHVAC.opa.HDifTil[1].weaBus.solZen = zonHVAC.opa.weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/ThermalZones/ISO13790/Examples/FreeFloatingHVAC.mo:30:3-33:22:writable] Warning: Equation 1616 (size: 1) weaDat.weaBus.alt = zonHVAC.weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.weaBus.alt, zonHVAC.weaBus.alt Equations used to solve those variables: Equation 855 (size: 1): weaDat.altitude.y = weaDat.weaBus.alt Equation 1525 (size: 1): zonHVAC.opa.weaBus.alt = zonHVAC.weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Tables.mo:84:9-84:55:writable] Warning: Equation 45 (size: 1) weaDat.datRea30Min.y[1] = Modelica.Blocks.Tables.Internal.getTable1DValue(weaDat.datRea30Min.tableID, 1, weaDat.datRea30Min.u) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.datRea30Min.u, weaDat.datRea30Min.y[1] Equations used to solve those variables: Equation 786 (size: 1): weaDat.conTimMin.calTim = weaDat.datRea30Min.u Equation 831 (size: 1): weaDat.datRea30Min.y[1] = weaDat.souSelRad.HGloHorFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Tables.mo:84:9-84:55:writable] Warning: Equation 47 (size: 1) weaDat.datRea30Min.y[3] = Modelica.Blocks.Tables.Internal.getTable1DValue(weaDat.datRea30Min.tableID, 3, weaDat.datRea30Min.u) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.datRea30Min.u, weaDat.datRea30Min.y[3] Equations used to solve those variables: Equation 786 (size: 1): weaDat.conTimMin.calTim = weaDat.datRea30Min.u Equation 829 (size: 1): weaDat.datRea30Min.y[3] = weaDat.souSelRad.HDifHorFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/BoundaryConditions/SolarGeometry/BaseClasses/SolarHourAngle.mo:13:3-14:43:writable] Warning: Equation 59 (size: 1) weaDat.solHouAng.solHouAng = 0.2617993877991494 * (-12.0 + 0.0002777777777777778 * weaDat.solHouAng.solTim) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.solHouAng.solTim, weaDat.solHouAng.solHouAng Equations used to solve those variables: Equation 797 (size: 1): weaDat.solHouAng.solHouAng = weaDat.zenAng.solHouAng Equation 798 (size: 1): weaDat.solHouAng.solTim = weaDat.solTim.solTim Error: Internal error SimCode: The model IBPSA.ThermalZones.ISO13790.Examples.HeatingCoolingHVAC could not be translated to FMU