Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ClaRa_dev_ClaRa.Components.TurboMachines.Compressors.Check.Test_MassFlow_VIGVControlled.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.0-main/package.mo", uses=false) loadFile("/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/package.mo", uses=false) Using package ClaRa with version 1.8.0 (/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/package.mo) Using package TILMedia with version 1.8.0 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.0-main/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ClaRa.Components.TurboMachines.Compressors.Check.Test_MassFlow_VIGVControlled,fileNamePrefix="ClaRa_dev_ClaRa_Components_TurboMachines_Compressors_Check_Test_MassFlow_VIGVControlled",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ClaRa.Components.TurboMachines.Compressors.Check.Test_MassFlow_VIGVControlled,fileNamePrefix="ClaRa_dev_ClaRa_Components_TurboMachines_Compressors_Check_Test_MassFlow_VIGVControlled",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.005001/0.005001, allocations: 184.8 kB / 7.456 MB, free: 2.512 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.262/1.262, allocations: 221.4 MB / 229.3 MB, free: 3.395 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009685/0.0009687, allocations: 88.3 kB / 280.1 MB, free: 1.348 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.0-main/package.mo): time 0.08617/0.08617, allocations: 20.17 MB / 351.1 MB, free: 10.41 MB / 298.7 MB [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Components/Sensors/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: TinySensorGas_L1_O2dry [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/ControlVolumes/Fundamentals/PressureLoss/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: TubeType_L2 TubeType_L3 ShellType_L2 ShellType_L3 [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/ControlVolumes/Fundamentals/HeatTransport/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: TubeType_L2 TubeType_L3 ShellType_L2 ShellType_L3 [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/ControlVolumes/FluidVolumes/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: VolumeVLE_2 VolumeVLE_3_TwoZones Notification: Performance of loadFile(/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/package.mo): time 1.035/1.035, allocations: 127.6 MB / 0.5229 GB, free: 4.723 MB / 346.8 MB Notification: Performance of FrontEnd - loaded program: time 0.2146/1.25, allocations: 89.71 MB / 0.6105 GB, free: 10.81 MB / 442.8 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5625/1.812, allocations: 82.83 MB / 0.6914 GB, free: 33.85 MB / 474.8 MB Notification: Performance of FrontEnd - scodeFlatten: time 3.822/5.634, allocations: 1.477 GB / 2.168 GB, free: 85.52 MB / 0.7137 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003243/5.634, allocations: 99.84 kB / 2.168 GB, free: 85.43 MB / 0.7137 GB [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/Interfaces/CycleSumPort.mo:2:1-38:17:writable] Warning: Connector .ClaRa.Basics.Interfaces.CycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/SimCenter.mo:104:2-104:69:writable] Error: Function parameter vleFluidPointer was not given by the function call, and does not have a default value. Error: Error occurred while flattening model ClaRa.Components.TurboMachines.Compressors.Check.Test_MassFlow_VIGVControlled Error: Internal error SimCode: The model ClaRa.Components.TurboMachines.Compressors.Check.Test_MassFlow_VIGVControlled could not be translated to FMU