Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ClaRa_dev_ClaRa.Components.Sensors.Check.TestVLESensors.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.0-main/package.mo", uses=false) loadFile("/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/package.mo", uses=false) Using package ClaRa with version 1.8.0 (/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/package.mo) Using package TILMedia with version 1.8.0 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.0-main/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ClaRa.Components.Sensors.Check.TestVLESensors,fileNamePrefix="ClaRa_dev_ClaRa_Components_Sensors_Check_TestVLESensors",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ClaRa.Components.Sensors.Check.TestVLESensors,fileNamePrefix="ClaRa_dev_ClaRa_Components_Sensors_Check_TestVLESensors",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.004611/0.004611, allocations: 180.6 kB / 7.455 MB, free: 2.512 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.48/1.48, allocations: 221.4 MB / 229.3 MB, free: 3.008 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009941/0.0009942, allocations: 89.41 kB / 280.1 MB, free: 1.242 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.0-main/package.mo): time 0.09236/0.09236, allocations: 20.17 MB / 351.1 MB, free: 10.3 MB / 298.7 MB [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Components/Sensors/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: TinySensorGas_L1_O2dry [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/ControlVolumes/Fundamentals/PressureLoss/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: TubeType_L2 TubeType_L3 ShellType_L2 ShellType_L3 [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/ControlVolumes/Fundamentals/HeatTransport/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: TubeType_L2 TubeType_L3 ShellType_L2 ShellType_L3 [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/ControlVolumes/FluidVolumes/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: VolumeVLE_2 VolumeVLE_3_TwoZones Notification: Performance of loadFile(/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/package.mo): time 1.118/1.118, allocations: 127.6 MB / 0.5229 GB, free: 4.781 MB / 346.8 MB Warning: Ignoring unknown experiment annotation option: __Dymola_Algorithm = "Sdirk34hw" Notification: Performance of FrontEnd - loaded program: time 0.2324/1.35, allocations: 89.71 MB / 0.6105 GB, free: 10.89 MB / 442.8 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5323/1.883, allocations: 82.83 MB / 0.6914 GB, free: 33.7 MB / 474.8 MB Notification: Performance of FrontEnd - scodeFlatten: time 2.802/4.684, allocations: 1.248 GB / 1.939 GB, free: 30.03 MB / 0.7137 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002951/4.685, allocations: 91.86 kB / 1.939 GB, free: 29.95 MB / 0.7137 GB [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/Basics/Interfaces/CycleSumPort.mo:2:1-38:17:writable] Warning: Connector .ClaRa.Basics.Interfaces.CycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/mnt/ReferenceFiles/ExtraLibs/packaged/ClaRa/SimCenter.mo:104:2-104:69:writable] Error: Function parameter vleFluidPointer was not given by the function call, and does not have a default value. Error: Error occurred while flattening model ClaRa.Components.Sensors.Check.TestVLESensors Error: Internal error SimCode: The model ClaRa.Components.Sensors.Check.TestVLESensors could not be translated to FMU