Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.TwoIdenticalZones.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.TwoIdenticalZones,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Validation_ThermalZone_TwoIdenticalZones",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.TwoIdenticalZones,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Validation_ThermalZone_TwoIdenticalZones",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.433/1.433, allocations: 285.5 MB / 292.8 MB, free: 10.5 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001006/0.001006, allocations: 185.3 kB / 361.1 MB, free: 7.078 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.306/1.306, allocations: 205.1 MB / 0.6195 GB, free: 10.28 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008284/0.0008285, allocations: 96.42 kB / 0.7326 GB, free: 44.22 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2687/0.2696, allocations: 121.4 MB / 0.8511 GB, free: 2.871 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6774/0.947, allocations: 115.3 MB / 0.9638 GB, free: 78.26 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.205/5.152, allocations: 2.117 GB / 3.08 GB, free: 347 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002707/5.152, allocations: 94.08 kB / 3.081 GB, free: 347 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/Validation/ThermalZone/TwoIdenticalZones.mo:73:17-73:38:writable] Error: Class .Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.TwoIdenticalZones.Zone$zon1.Medium not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Error: Class Medium.setState_pTX not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc (looking for a function or record). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/Validation/ThermalZone/TwoIdenticalZones.mo:73:17-73:38:writable] Error: Class .Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.TwoIdenticalZones.Zone$zon1.Medium not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Error: Class Medium.ThermodynamicState not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc while instantiating zon1.duc.sta_default. Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.TwoIdenticalZones Error: Internal error SimCode: The model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.TwoIdenticalZones could not be translated to FMU