Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.43/1.43, allocations: 285.5 MB / 292.8 MB, free: 9.805 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001008/0.001009, allocations: 185.2 kB / 361.1 MB, free: 396 kB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.238/1.238, allocations: 205.1 MB / 0.6195 GB, free: 2.895 MB / 442.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008439/0.000844, allocations: 96.77 kB / 0.7326 GB, free: 1.055 MB / 0.5417 GB Notification: Performance of FrontEnd - loaded program: time 0.4951/0.496, allocations: 121.4 MB / 0.8512 GB, free: 151.8 MB / 0.6355 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.196/0.692, allocations: 115.3 MB / 0.9638 GB, free: 56.29 MB / 0.6355 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.187/4.879, allocations: 2.241 GB / 3.204 GB, free: 113.8 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003497/4.88, allocations: 108 kB / 3.205 GB, free: 113.7 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF could not be translated to FMU