Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Electrical_AC_ThreePhasesUnbalanced_Lines_Examples_ACLine",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Electrical_AC_ThreePhasesUnbalanced_Lines_Examples_ACLine",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.305/1.305, allocations: 285.5 MB / 292.8 MB, free: 10.44 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009236/0.0009236, allocations: 181.2 kB / 361.1 MB, free: 7.102 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.006/1.006, allocations: 205.1 MB / 0.6195 GB, free: 10.29 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007498/0.0007499, allocations: 93.59 kB / 0.7326 GB, free: 44.24 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.1746/0.1754, allocations: 121.5 MB / 0.8512 GB, free: 2.852 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4016/0.577, allocations: 115.3 MB / 0.9638 GB, free: 78.04 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.1677/0.7447, allocations: 183.5 MB / 1.143 GB, free: 4.387 MB / 0.7448 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002273/0.745, allocations: 95.59 kB / 1.143 GB, free: 4.297 MB / 0.7448 GB Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine Error: Internal error SimCode: The model Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine could not be translated to FMU