Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Utilities.Plotters.Examples.SingleZoneVAV.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Utilities.Plotters.Examples.SingleZoneVAV,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Utilities_Plotters_Examples_SingleZoneVAV",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Utilities.Plotters.Examples.SingleZoneVAV,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Utilities_Plotters_Examples_SingleZoneVAV",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.319/1.319, allocations: 249.4 MB / 256.7 MB, free: 7.027 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001164/0.001164, allocations: 180.6 kB / 316 MB, free: 3.535 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.231/1.231, allocations: 205.2 MB / 0.5667 GB, free: 15.66 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009011/0.000901, allocations: 101.5 kB / 0.671 GB, free: 4.785 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.3539/0.3548, allocations: 112.5 MB / 0.7808 GB, free: 103 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.177/0.5319, allocations: 106.3 MB / 0.8846 GB, free: 12.56 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.356/4.888, allocations: 2.703 GB / 3.588 GB, free: 81.58 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000218/4.888, allocations: 92.7 kB / 3.588 GB, free: 81.49 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Air/Systems/SingleZone/VAV/ChillerDXHeatingEconomizer.mo:108:3-119:69:writable] Error: component hvac.heaCoi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Utilities.Plotters.Examples.SingleZoneVAV Error: Internal error SimCode: The model Buildings.Utilities.Plotters.Examples.SingleZoneVAV could not be translated to FMU