Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.275/1.275, allocations: 249.4 MB / 256.7 MB, free: 6.98 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009754/0.0009756, allocations: 181.2 kB / 316 MB, free: 3.543 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.311/1.311, allocations: 205.2 MB / 0.5667 GB, free: 15.64 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008926/0.0008925, allocations: 89.86 kB / 0.671 GB, free: 4.766 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.4086/0.4096, allocations: 112.5 MB / 0.7808 GB, free: 103 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2155/0.6251, allocations: 106.3 MB / 0.8847 GB, free: 12.57 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.332/4.957, allocations: 2.36 GB / 3.245 GB, free: 11.55 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004007/4.958, allocations: 114.6 kB / 3.245 GB, free: 11.49 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF could not be translated to FMU