Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_HeatPumps_Validation_ScrollWaterToWater_TemperatureProtection",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_HeatPumps_Validation_ScrollWaterToWater_TemperatureProtection",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.262/1.262, allocations: 249.4 MB / 256.7 MB, free: 7.07 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00101/0.00101, allocations: 185.2 kB / 316 MB, free: 3.551 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.159/1.159, allocations: 205.1 MB / 0.5667 GB, free: 15.76 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008948/0.0008948, allocations: 88.88 kB / 0.671 GB, free: 4.883 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.3518/0.3527, allocations: 112.5 MB / 0.7808 GB, free: 103 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1594/0.5122, allocations: 106.3 MB / 0.8846 GB, free: 12.56 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.085/1.598, allocations: 416.2 MB / 1.291 GB, free: 289.1 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002689/1.598, allocations: 91.67 kB / 1.291 GB, free: 289.1 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection Error: Internal error SimCode: The model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection could not be translated to FMU