Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_ShiftAggregationCells",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_ShiftAggregationCells",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.25/1.25, allocations: 249.4 MB / 256.7 MB, free: 7.039 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009187/0.0009186, allocations: 192.4 kB / 316 MB, free: 3.562 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.183/1.183, allocations: 205.2 MB / 0.5667 GB, free: 15.72 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008243/0.0008246, allocations: 84.86 kB / 0.671 GB, free: 4.859 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.3213/0.3221, allocations: 112.5 MB / 0.7808 GB, free: 103 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1534/0.4756, allocations: 106.3 MB / 0.8847 GB, free: 12.54 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.4717/0.9473, allocations: 132.8 MB / 1.014 GB, free: 5.809 MB / 0.6355 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002499/0.9476, allocations: 102 kB / 1.014 GB, free: 5.742 MB / 0.6355 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/ShiftAggregationCells.mo:15:5-20:21:writable] Error: Type mismatch for named argument in Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.shiftAggregationCells(rCel={1, 1, 1, 2, 2}). The argument has type: Integer[5] expected type: Real[i] Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells Error: Internal error SimCode: The model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells could not be translated to FMU