Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_CarnotVerifyEtaCarnot",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_CarnotVerifyEtaCarnot",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.254/1.254, allocations: 249.4 MB / 256.7 MB, free: 6.957 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00102/0.00102, allocations: 192.3 kB / 316 MB, free: 3.562 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.112/1.112, allocations: 205.1 MB / 0.5667 GB, free: 15.62 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008999/0.0008997, allocations: 79.3 kB / 0.671 GB, free: 4.762 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.3264/0.3274, allocations: 112.5 MB / 0.7808 GB, free: 103 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1593/0.4867, allocations: 106.3 MB / 0.8846 GB, free: 12.59 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.004/1.491, allocations: 417.8 MB / 1.293 GB, free: 324.1 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002581/1.491, allocations: 90.09 kB / 1.293 GB, free: 324.1 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Chillers/Validation/CarnotVerifyEtaCarnot.mo:53:3-71:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot could not be translated to FMU