Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.218/1.218, allocations: 249.4 MB / 256.7 MB, free: 7.082 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009521/0.0009522, allocations: 181.2 kB / 316 MB, free: 3.566 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.169/1.169, allocations: 205.1 MB / 0.5667 GB, free: 15.64 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008771/0.0008772, allocations: 88.31 kB / 0.671 GB, free: 4.77 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.3433/0.3442, allocations: 112.5 MB / 0.7808 GB, free: 103 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1812/0.5255, allocations: 106.3 MB / 0.8847 GB, free: 12.55 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.776/4.301, allocations: 2.221 GB / 3.106 GB, free: 179 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002683/4.301, allocations: 103.9 kB / 3.106 GB, free: 178.9 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Error: Internal error SimCode: The model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels could not be translated to FMU