Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_TwoIdenticalZones",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_TwoIdenticalZones",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.896/1.896, allocations: 390.4 MB / 397.7 MB, free: 11.27 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001031/0.001031, allocations: 182.8 kB / 490.8 MB, free: 1.973 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.222/1.222, allocations: 221.4 MB / 0.7863 GB, free: 13.68 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009308/0.000931, allocations: 80.7 kB / 0.9264 GB, free: 14.21 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 0.4935/0.4945, allocations: 149.1 MB / 1.072 GB, free: 182.5 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2125/0.707, allocations: 143 MB / 1.212 GB, free: 40.02 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.071/3.778, allocations: 1.964 GB / 3.176 GB, free: 376.4 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002379/3.778, allocations: 94.08 kB / 3.176 GB, free: 376.4 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/Validation/ThermalZone/TwoIdenticalZones.mo:74:17-74:38:writable] Error: Class .Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.Zone$zon1.Medium not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Error: Class Medium.setState_pTX not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc (looking for a function or record). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/Validation/ThermalZone/TwoIdenticalZones.mo:74:17-74:38:writable] Error: Class .Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.Zone$zon1.Medium not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Error: Class Medium.ThermodynamicState not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc while instantiating zon1.duc.sta_default. Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones Error: Internal error SimCode: The model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones could not be translated to FMU