Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyPartition",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyPartition",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.834/1.834, allocations: 390.4 MB / 397.7 MB, free: 10.62 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009916/0.0009916, allocations: 185.3 kB / 490.8 MB, free: 11.16 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.106/1.106, allocations: 221.4 MB / 0.7863 GB, free: 13.55 MB / 0.5886 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008415/0.0008415, allocations: 102.8 kB / 0.9264 GB, free: 20.91 MB / 0.6042 GB Notification: Performance of FrontEnd - loaded program: time 0.2423/0.2431, allocations: 149.1 MB / 1.072 GB, free: 15.91 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.503/0.7461, allocations: 143 MB / 1.212 GB, free: 53.48 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.586/4.332, allocations: 2.063 GB / 3.274 GB, free: 403.5 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002913/4.333, allocations: 99.45 kB / 3.274 GB, free: 403.4 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:246:11-246:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition could not be translated to FMU