Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_Initialization_MixedAir",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_Initialization_MixedAir",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.859/1.859, allocations: 390.4 MB / 397.7 MB, free: 11.31 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009566/0.0009566, allocations: 181.2 kB / 490.8 MB, free: 1.953 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.215/1.215, allocations: 221.4 MB / 0.7863 GB, free: 13.64 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009784/0.0009783, allocations: 92.97 kB / 0.9264 GB, free: 14.18 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 0.5161/0.5171, allocations: 149.1 MB / 1.072 GB, free: 182.5 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2229/0.7401, allocations: 143 MB / 1.212 GB, free: 40.03 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.633/4.373, allocations: 2.067 GB / 3.279 GB, free: 239.4 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000197/4.373, allocations: 95.88 kB / 3.279 GB, free: 239.3 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir could not be translated to FMU