Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_latest_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_latest_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.84/1.84, allocations: 390.4 MB / 397.7 MB, free: 11.27 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001045/0.001045, allocations: 185.2 kB / 490.8 MB, free: 1.949 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.144/1.144, allocations: 221.3 MB / 0.7863 GB, free: 13.65 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009101/0.0009101, allocations: 87.86 kB / 0.9264 GB, free: 14.18 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 0.4329/0.4338, allocations: 149.1 MB / 1.072 GB, free: 182.5 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1943/0.6281, allocations: 143 MB / 1.212 GB, free: 40.01 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.558/3.187, allocations: 1.762 GB / 2.974 GB, free: 109.1 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002358/3.187, allocations: 99.92 kB / 2.974 GB, free: 109 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Error: Internal error SimCode: The model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels could not be translated to FMU