Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,fileNamePrefix="Buildings_latest_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,fileNamePrefix="Buildings_latest_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.842/1.842, allocations: 390.4 MB / 397.7 MB, free: 11.3 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009162/0.0009161, allocations: 185.2 kB / 490.8 MB, free: 1.957 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.134/1.134, allocations: 221.3 MB / 0.7863 GB, free: 13.67 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008385/0.0008386, allocations: 96.66 kB / 0.9264 GB, free: 14.2 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 0.5054/0.5062, allocations: 149.1 MB / 1.072 GB, free: 182.5 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2189/0.7252, allocations: 143 MB / 1.212 GB, free: 40.02 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.253/1.979, allocations: 0.5366 GB / 1.748 GB, free: 397.4 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002323/1.979, allocations: 106.6 kB / 1.748 GB, free: 397.4 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPum[1].pressure.V_flow={0.01222428571428572, 0.03667285714285714, 0.06112142857142858, 0.07334571428571428}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic$perPum (looking for a function or record). Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary Error: Internal error SimCode: The model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary could not be translated to FMU