Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36,fileNamePrefix="Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36,fileNamePrefix="Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.84/1.84, allocations: 390.4 MB / 397.7 MB, free: 11.23 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001013/0.001014, allocations: 181.3 kB / 490.8 MB, free: 1.93 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.158/1.158, allocations: 221.3 MB / 0.7863 GB, free: 13.7 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009238/0.0009239, allocations: 87.12 kB / 0.9264 GB, free: 14.23 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 0.4341/0.4351, allocations: 149.1 MB / 1.072 GB, free: 182.5 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2008/0.6359, allocations: 143 MB / 1.212 GB, free: 40 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.747/4.383, allocations: 2.461 GB / 3.673 GB, free: 363.4 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002199/4.383, allocations: 97.52 kB / 3.673 GB, free: 363.4 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36 Error: Internal error SimCode: The model Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36 could not be translated to FMU