Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_TwoIdenticalZones",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_TwoIdenticalZones",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.98/1.98, allocations: 387.2 MB / 394.5 MB, free: 13.64 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001178/0.001178, allocations: 176.3 kB / 487 MB, free: 5.383 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.491/1.491, allocations: 221.3 MB / 0.7819 GB, free: 1.379 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009696/0.0009696, allocations: 94.33 kB / 0.9213 GB, free: 2.641 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.5851/0.5861, allocations: 148.5 MB / 1.066 GB, free: 168.2 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2916/0.8778, allocations: 142.3 MB / 1.205 GB, free: 26.17 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.054/4.932, allocations: 1.963 GB / 3.168 GB, free: 357.5 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002536/4.932, allocations: 99.88 kB / 3.169 GB, free: 357.4 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/Validation/ThermalZone/TwoIdenticalZones.mo:74:17-74:38:writable] Error: Class .Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.Zone$zon1.Medium not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Error: Class Medium.setState_pTX not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc (looking for a function or record). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/Validation/ThermalZone/TwoIdenticalZones.mo:74:17-74:38:writable] Error: Class .Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.Zone$zon1.Medium not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Error: Class Medium.ThermodynamicState not found in scope Buildings.Fluid.FixedResistances.PressureDrop$zon1$duc while instantiating zon1.duc.sta_default. Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones Error: Internal error SimCode: The model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones could not be translated to FMU