Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.965/1.965, allocations: 387.2 MB / 394.5 MB, free: 13.66 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001126/0.001126, allocations: 189.2 kB / 487 MB, free: 5.406 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.427/1.427, allocations: 221.3 MB / 0.7819 GB, free: 1.426 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.000958/0.000958, allocations: 98.8 kB / 0.9213 GB, free: 2.664 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.5325/0.5335, allocations: 148.5 MB / 1.066 GB, free: 168.2 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.235/0.7685, allocations: 142.3 MB / 1.205 GB, free: 26.13 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.103/3.871, allocations: 1.733 GB / 2.938 GB, free: 124.3 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002638/3.872, allocations: 87.95 kB / 2.938 GB, free: 124.2 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/OutputVariable.mo:39:3-71:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable Error: Internal error SimCode: The model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable could not be translated to FMU