Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Constructions_Examples_ExteriorWallTwoWindows",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Constructions_Examples_ExteriorWallTwoWindows",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.999/1.999, allocations: 387.2 MB / 394.5 MB, free: 13.27 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001072/0.001072, allocations: 188.1 kB / 487 MB, free: 0.7266 MB / 378.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.357/1.357, allocations: 221.3 MB / 0.7819 GB, free: 6.762 MB / 0.573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008745/0.0008745, allocations: 103.9 kB / 0.9213 GB, free: 43.68 MB / 0.6198 GB Notification: Performance of FrontEnd - loaded program: time 0.2637/0.2646, allocations: 148.5 MB / 1.066 GB, free: 7.496 MB / 0.7292 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6087/0.8733, allocations: 142.3 MB / 1.205 GB, free: 72.64 MB / 0.7917 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.299/4.173, allocations: 1.788 GB / 2.993 GB, free: 258.1 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002561/4.173, allocations: 94.39 kB / 2.994 GB, free: 258 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/Detailed/Constructions/Examples/ExteriorWallTwoWindows.mo:61:5-61:18:writable] Error: Type mismatch in binding A = {30.0, 30.0}, expected subtype of Real, got type Real[2]. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows could not be translated to FMU