Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="Buildings_9_Buildings_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="Buildings_9_Buildings_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.998/1.998, allocations: 387.3 MB / 394.5 MB, free: 13.3 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00127/0.001271, allocations: 180.8 kB / 487 MB, free: 0.7266 MB / 378.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.455/1.455, allocations: 221.3 MB / 0.7819 GB, free: 6.82 MB / 0.573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009748/0.0009749, allocations: 104.8 kB / 0.9213 GB, free: 43.71 MB / 0.6198 GB Notification: Performance of FrontEnd - loaded program: time 0.3273/0.3283, allocations: 148.5 MB / 1.066 GB, free: 7.535 MB / 0.7292 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7289/1.057, allocations: 142.3 MB / 1.205 GB, free: 72.8 MB / 0.7917 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.081/2.138, allocations: 433.9 MB / 1.629 GB, free: 173.3 MB / 1.01 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002674/2.138, allocations: 88.42 kB / 1.629 GB, free: 173.3 MB / 1.01 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Chillers/Examples/Carnot_TEva.mo:18:3-32:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature could not be translated to FMU