Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot,fileNamePrefix="Buildings_9_Buildings_Fluid_Chillers_Validation_CarnotVerifyEtaCarnot",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot,fileNamePrefix="Buildings_9_Buildings_Fluid_Chillers_Validation_CarnotVerifyEtaCarnot",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.122/2.122, allocations: 387.2 MB / 394.5 MB, free: 13.65 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001114/0.001114, allocations: 184.6 kB / 487 MB, free: 5.375 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.39/1.39, allocations: 221.3 MB / 0.7819 GB, free: 1.41 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001084/0.001084, allocations: 100.4 kB / 0.9213 GB, free: 2.648 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.6382/0.6393, allocations: 148.4 MB / 1.066 GB, free: 168.2 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2762/0.9155, allocations: 142.3 MB / 1.205 GB, free: 26.18 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.007/1.923, allocations: 436.5 MB / 1.632 GB, free: 3.406 MB / 1.057 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002583/1.923, allocations: 92.91 kB / 1.632 GB, free: 3.359 MB / 1.057 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Chillers/Validation/CarnotVerifyEtaCarnot.mo:52:3-70:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot could not be translated to FMU