Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Fluid.Chillers.Examples.Carnot_TEva.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Examples.Carnot_TEva,fileNamePrefix="Buildings_9_Buildings_Fluid_Chillers_Examples_Carnot_TEva",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Examples.Carnot_TEva,fileNamePrefix="Buildings_9_Buildings_Fluid_Chillers_Examples_Carnot_TEva",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.985/1.985, allocations: 387.2 MB / 394.5 MB, free: 13.64 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00115/0.00115, allocations: 176.7 kB / 487 MB, free: 5.379 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.301/1.301, allocations: 221.3 MB / 0.7819 GB, free: 1.395 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009492/0.0009492, allocations: 100.9 kB / 0.9213 GB, free: 2.66 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.5442/0.5452, allocations: 148.5 MB / 1.066 GB, free: 168.2 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.23/0.7752, allocations: 142.3 MB / 1.205 GB, free: 26.17 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9537/1.729, allocations: 433.7 MB / 1.629 GB, free: 6.094 MB / 1.057 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002824/1.729, allocations: 89.64 kB / 1.629 GB, free: 6.051 MB / 1.057 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Chillers/Examples/Carnot_TEva.mo:18:3-32:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Examples.Carnot_TEva Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Examples.Carnot_TEva could not be translated to FMU