Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_9_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_9_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.81/1.81, allocations: 387.2 MB / 394.5 MB, free: 13.67 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009122/0.0009123, allocations: 169.4 kB / 487 MB, free: 5.387 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.164/1.164, allocations: 221.3 MB / 0.7819 GB, free: 1.457 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008686/0.0008687, allocations: 100.5 kB / 0.9213 GB, free: 2.711 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.4319/0.4328, allocations: 148.5 MB / 1.066 GB, free: 168.2 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1954/0.6282, allocations: 142.3 MB / 1.205 GB, free: 26.17 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.596/3.225, allocations: 1.761 GB / 2.966 GB, free: 92.41 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002344/3.225, allocations: 95.94 kB / 2.967 GB, free: 92.32 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Error: Internal error SimCode: The model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels could not be translated to FMU