Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36,fileNamePrefix="Buildings_9_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36,fileNamePrefix="Buildings_9_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.83/1.83, allocations: 387.2 MB / 394.5 MB, free: 13.62 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001028/0.001028, allocations: 184.5 kB / 487 MB, free: 5.375 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.263/1.263, allocations: 221.3 MB / 0.7819 GB, free: 1.41 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009215/0.0009215, allocations: 99.55 kB / 0.9213 GB, free: 2.66 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.4658/0.4668, allocations: 148.5 MB / 1.066 GB, free: 168.2 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2092/0.676, allocations: 142.3 MB / 1.205 GB, free: 26.14 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.899/4.575, allocations: 2.427 GB / 3.632 GB, free: 329.4 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002094/4.575, allocations: 103.8 kB / 3.633 GB, free: 329.3 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36 Error: Internal error SimCode: The model Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36 could not be translated to FMU