Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Utilities.Plotters.Examples.SingleZoneVAV.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Utilities.Plotters.Examples.SingleZoneVAV,fileNamePrefix="Buildings_8_Buildings_Utilities_Plotters_Examples_SingleZoneVAV",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Utilities.Plotters.Examples.SingleZoneVAV,fileNamePrefix="Buildings_8_Buildings_Utilities_Plotters_Examples_SingleZoneVAV",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.588/1.588, allocations: 289.8 MB / 297.1 MB, free: 6.609 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001183/0.001183, allocations: 181.2 kB / 366.3 MB, free: 1.93 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.482/1.482, allocations: 205.2 MB / 0.6256 GB, free: 7.422 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008919/0.000892, allocations: 82.14 kB / 0.7395 GB, free: 39.86 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2735/0.2744, allocations: 122.4 MB / 0.8591 GB, free: 13.47 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6457/0.9202, allocations: 116.3 MB / 0.9726 GB, free: 76.02 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.931/6.851, allocations: 2.593 GB / 3.566 GB, free: 305 MB / 0.9636 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002855/6.852, allocations: 93.39 kB / 3.566 GB, free: 304.9 MB / 0.9636 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Air/Systems/SingleZone/VAV/ChillerDXHeatingEconomizer.mo:113:3-124:69:writable] Error: component hvac.heaCoi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Utilities.Plotters.Examples.SingleZoneVAV Error: Internal error SimCode: The model Buildings.Utilities.Plotters.Examples.SingleZoneVAV could not be translated to FMU