Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="Buildings_8_Buildings_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="Buildings_8_Buildings_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.672/1.672, allocations: 289.8 MB / 297.1 MB, free: 6.699 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001484/0.001485, allocations: 177.3 kB / 366.3 MB, free: 1.992 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.598/1.598, allocations: 205.1 MB / 0.6256 GB, free: 7.461 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009936/0.0009933, allocations: 85.52 kB / 0.7395 GB, free: 39.88 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2866/0.2877, allocations: 122.4 MB / 0.8591 GB, free: 13.49 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.732/1.02, allocations: 116.3 MB / 0.9726 GB, free: 76.33 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.053/2.072, allocations: 422.6 MB / 1.385 GB, free: 129.6 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002464/2.073, allocations: 88.45 kB / 1.385 GB, free: 129.6 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity could not be translated to FMU