Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.Infiltration.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.Infiltration,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_ThermalZone_Infiltration",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.Infiltration,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_ThermalZone_Infiltration",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.35/2.35, allocations: 284.8 MB / 292.1 MB, free: 10.79 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001625/0.001625, allocations: 177.3 kB / 360.3 MB, free: 7.562 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.893/1.893, allocations: 205.1 MB / 0.6187 GB, free: 13.23 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001276/0.001275, allocations: 86.16 kB / 0.7317 GB, free: 45.16 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2653/0.2666, allocations: 121.4 MB / 0.8502 GB, free: 3.953 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6102/0.8769, allocations: 115.2 MB / 0.9627 GB, free: 78.32 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.967/6.844, allocations: 2.47 GB / 3.432 GB, free: 269.2 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003765/6.845, allocations: 99.81 kB / 3.432 GB, free: 269.2 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.Infiltration Error: Internal error SimCode: The model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.Infiltration could not be translated to FMU