Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyPartition",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyPartition",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.226/2.226, allocations: 284.8 MB / 292.1 MB, free: 10.72 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001607/0.001607, allocations: 181.2 kB / 360.3 MB, free: 7.527 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.724/1.724, allocations: 205.1 MB / 0.6187 GB, free: 13.2 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001216/0.001215, allocations: 90.3 kB / 0.7317 GB, free: 45.09 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2746/0.2758, allocations: 121.4 MB / 0.8502 GB, free: 3.902 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6225/0.8984, allocations: 115.2 MB / 0.9627 GB, free: 78.43 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.321/6.219, allocations: 2.213 GB / 3.176 GB, free: 260.8 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003913/6.22, allocations: 101 kB / 3.176 GB, free: 260.8 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:249:11-249:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition could not be translated to FMU