Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_Detailed_Validation_Initialization_MixedAir",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_Detailed_Validation_Initialization_MixedAir",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.26/2.26, allocations: 284.8 MB / 292.1 MB, free: 10.71 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002585/0.002586, allocations: 181.2 kB / 360.3 MB, free: 7.516 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.761/1.761, allocations: 205.1 MB / 0.6187 GB, free: 13.2 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001302/0.001301, allocations: 82.28 kB / 0.7317 GB, free: 45.09 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2762/0.2776, allocations: 121.4 MB / 0.8502 GB, free: 3.895 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6434/0.921, allocations: 115.2 MB / 0.9627 GB, free: 78.36 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.426/6.347, allocations: 2.217 GB / 3.18 GB, free: 167.1 MB / 0.9323 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004135/6.347, allocations: 98.81 kB / 3.18 GB, free: 167 MB / 0.9323 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir could not be translated to FMU