Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_etaPL",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_etaPL",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.488/2.488, allocations: 284.8 MB / 292.1 MB, free: 10.79 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001619/0.001618, allocations: 173.3 kB / 360.3 MB, free: 7.555 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.909/1.909, allocations: 205.1 MB / 0.6187 GB, free: 13.2 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001699/0.001698, allocations: 88.45 kB / 0.7317 GB, free: 45.11 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.3373/0.3391, allocations: 121.4 MB / 0.8502 GB, free: 3.93 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6515/0.9906, allocations: 115.2 MB / 0.9627 GB, free: 78.73 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.067/2.058, allocations: 421.6 MB / 1.374 GB, free: 146.9 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0007331/2.059, allocations: 86.98 kB / 1.375 GB, free: 146.8 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL Error: Internal error SimCode: The model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL could not be translated to FMU