Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.807/2.807, allocations: 284.8 MB / 292.1 MB, free: 9.879 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001678/0.001677, allocations: 178.8 kB / 360.3 MB, free: 0.9961 MB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.871/1.871, allocations: 205.1 MB / 0.6187 GB, free: 3.281 MB / 442.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001256/0.001255, allocations: 98.2 kB / 0.7317 GB, free: 1.789 MB / 0.5417 GB Notification: Performance of FrontEnd - loaded program: time 0.5717/0.573, allocations: 121.4 MB / 0.8502 GB, free: 149.8 MB / 0.6355 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2311/0.8041, allocations: 115.3 MB / 0.9628 GB, free: 56.96 MB / 0.6355 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.112/1.916, allocations: 421.6 MB / 1.374 GB, free: 3.418 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003217/1.916, allocations: 86.88 kB / 1.375 GB, free: 3.375 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity Error: Internal error SimCode: The model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity could not be translated to FMU