Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.479/2.479, allocations: 284.8 MB / 292.1 MB, free: 10.65 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001638/0.001638, allocations: 181.2 kB / 360.3 MB, free: 7.41 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.795/1.795, allocations: 205.1 MB / 0.6187 GB, free: 12.33 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001185/0.001184, allocations: 77.73 kB / 0.7317 GB, free: 44.92 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2749/0.2761, allocations: 121.4 MB / 0.8502 GB, free: 3.68 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6663/0.9425, allocations: 115.2 MB / 0.9628 GB, free: 78.35 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.2725/1.215, allocations: 167.7 MB / 1.127 GB, free: 4.906 MB / 0.7292 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004121/1.216, allocations: 104.5 kB / 1.127 GB, free: 4.805 MB / 0.7292 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years Error: Internal error SimCode: The model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years could not be translated to FMU