Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.381/2.381, allocations: 284.8 MB / 292.1 MB, free: 10.77 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001621/0.001621, allocations: 177.3 kB / 360.3 MB, free: 7.566 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.801/1.801, allocations: 205.1 MB / 0.6187 GB, free: 13.23 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001253/0.001252, allocations: 98.38 kB / 0.7317 GB, free: 45.15 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.2978/0.2991, allocations: 121.4 MB / 0.8502 GB, free: 3.973 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7213/1.02, allocations: 115.2 MB / 0.9627 GB, free: 78.18 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.034/2.055, allocations: 421.4 MB / 1.374 GB, free: 147.1 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002799/2.055, allocations: 85.45 kB / 1.374 GB, free: 147 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity could not be translated to FMU