Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_RoomCapacityMultiplier",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 3.529/3.529, allocations: 248.6 MB / 255.9 MB, free: 7.105 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002926/0.002926, allocations: 189.2 kB / 315.1 MB, free: 4.258 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 3.278/3.278, allocations: 205.1 MB / 0.5658 GB, free: 380 kB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.002156/0.002155, allocations: 90.95 kB / 0.67 GB, free: 5.578 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.6972/0.6994, allocations: 112.4 MB / 0.7797 GB, free: 103.7 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3432/1.043, allocations: 106.2 MB / 0.8835 GB, free: 13.36 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.358/9.401, allocations: 2.369 GB / 3.253 GB, free: 9.062 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003589/9.401, allocations: 86.02 kB / 3.253 GB, free: 9.023 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:249:11-249:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier could not be translated to FMU