Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_VariableSpeed.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_VariableSpeed,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_VariableSpeed",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.205/2.205, allocations: 248.6 MB / 255.9 MB, free: 7.113 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001674/0.001674, allocations: 170.8 kB / 315.1 MB, free: 4.285 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.076/2.076, allocations: 205.1 MB / 0.5658 GB, free: 464 kB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001427/0.001427, allocations: 86.64 kB / 0.67 GB, free: 5.66 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.4696/0.4711, allocations: 112.4 MB / 0.7797 GB, free: 103.7 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2615/0.7327, allocations: 106.3 MB / 0.8835 GB, free: 13.37 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.544/2.277, allocations: 415.8 MB / 1.29 GB, free: 242.9 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003162/2.277, allocations: 89.31 kB / 1.29 GB, free: 242.9 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ReciprocatingCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_VariableSpeed Error: Internal error SimCode: The model Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_VariableSpeed could not be translated to FMU