Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_LowTemperature",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.161/2.161, allocations: 248.6 MB / 255.9 MB, free: 7.199 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00159/0.00159, allocations: 190.8 kB / 315.1 MB, free: 4.289 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.881/1.881, allocations: 205.1 MB / 0.5658 GB, free: 364 kB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001267/0.001267, allocations: 87.33 kB / 0.67 GB, free: 5.574 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.5179/0.5192, allocations: 112.4 MB / 0.7797 GB, free: 103.7 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2307/0.75, allocations: 106.3 MB / 0.8835 GB, free: 13.37 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.551/2.302, allocations: 415 MB / 1.289 GB, free: 243 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003645/2.302, allocations: 90.48 kB / 1.289 GB, free: 243 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature Error: Internal error SimCode: The model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature could not be translated to FMU