Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_ShiftAggregationCells",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.118/2.118, allocations: 248.6 MB / 255.9 MB, free: 7.121 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001611/0.00161, allocations: 181.3 kB / 315.1 MB, free: 4.297 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.886/1.886, allocations: 205.1 MB / 0.5658 GB, free: 324 kB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001301/0.001301, allocations: 90.64 kB / 0.67 GB, free: 5.523 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.4783/0.4796, allocations: 112.4 MB / 0.7798 GB, free: 103.6 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2186/0.6982, allocations: 106.3 MB / 0.8835 GB, free: 13.25 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.6271/1.325, allocations: 132.6 MB / 1.013 GB, free: 7.094 MB / 0.6355 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004893/1.326, allocations: 103.2 kB / 1.013 GB, free: 7.027 MB / 0.6355 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/ShiftAggregationCells.mo:15:5-20:21:writable] Error: Type mismatch for named argument in Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.shiftAggregationCells(rCel={1, 1, 1, 2, 2}). The argument has type: Integer[5] expected type: Real[i] Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells Error: Internal error SimCode: The model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells could not be translated to FMU