Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_TEva_etaPL.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_etaPL,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Chillers_Validation_Carnot_TEva_etaPL",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.001/2.001, allocations: 248.6 MB / 255.9 MB, free: 7.152 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001676/0.001675, allocations: 186.8 kB / 315.1 MB, free: 4.285 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.849/1.849, allocations: 205.1 MB / 0.5658 GB, free: 372 kB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001207/0.001206, allocations: 87.14 kB / 0.67 GB, free: 5.586 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.438/0.4392, allocations: 112.4 MB / 0.7797 GB, free: 103.7 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1932/0.6324, allocations: 106.2 MB / 0.8835 GB, free: 13.38 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.399/2.031, allocations: 414.8 MB / 1.289 GB, free: 244.7 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000324/2.032, allocations: 89.53 kB / 1.289 GB, free: 244.7 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_etaPL Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Validation.Carnot_TEva_etaPL could not be translated to FMU