Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Chillers_Validation_Carnot_TEva_2ndLaw",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.15/2.15, allocations: 248.6 MB / 255.9 MB, free: 1.117 MB / 194.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001657/0.001656, allocations: 175.6 kB / 315.1 MB, free: 9.543 MB / 258.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.774/1.774, allocations: 205.1 MB / 0.5658 GB, free: 13.95 MB / 434.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001258/0.001258, allocations: 88.92 kB / 0.6699 GB, free: 51.81 MB / 498.8 MB Notification: Performance of FrontEnd - loaded program: time 0.2483/0.2496, allocations: 112.4 MB / 0.7797 GB, free: 10.57 MB / 0.5496 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.248/0.4976, allocations: 106.2 MB / 0.8835 GB, free: 228 kB / 0.6433 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.31/1.807, allocations: 415.3 MB / 1.289 GB, free: 192.3 MB / 0.8308 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002715/1.808, allocations: 87.28 kB / 1.289 GB, free: 192.2 MB / 0.8308 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Validation/Carnot_TEva_2ndLaw.mo:81:5-96:72:writable] Error: Variable chi_b.chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_b$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw Error: Internal error SimCode: The model Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw could not be translated to FMU