Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall,fileNamePrefix="Buildings_7_0_0_Buildings_Experimental_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.199/2.199, allocations: 248.6 MB / 255.9 MB, free: 7.09 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001904/0.001903, allocations: 179.6 kB / 315.1 MB, free: 4.238 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.892/1.892, allocations: 205.1 MB / 0.5658 GB, free: 364 kB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001268/0.001267, allocations: 83.31 kB / 0.67 GB, free: 5.57 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.4861/0.4874, allocations: 112.4 MB / 0.7797 GB, free: 103.7 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2152/0.7027, allocations: 106.2 MB / 0.8835 GB, free: 13.35 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.821/7.524, allocations: 2.596 GB / 3.48 GB, free: 99.08 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002956/7.524, allocations: 90.7 kB / 3.48 GB, free: 99.04 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/HeatingCoolingHotwaterTimeSeries_dT.mo:235:3-247:75:writable] Error: Variable larOff.chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$larOff$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall Error: Internal error SimCode: The model Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall could not be translated to FMU