Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,fileNamePrefix="Buildings_7_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimaryLoadSide",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.249/2.249, allocations: 248.6 MB / 255.9 MB, free: 7.211 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.003118/0.003117, allocations: 181.2 kB / 315.1 MB, free: 4.301 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.861/1.861, allocations: 205.1 MB / 0.5658 GB, free: 376 kB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001312/0.001311, allocations: 90.72 kB / 0.67 GB, free: 5.582 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.4863/0.4876, allocations: 112.4 MB / 0.7797 GB, free: 103.7 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2327/0.7203, allocations: 106.2 MB / 0.8835 GB, free: 13.36 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.7/2.42, allocations: 0.5014 GB / 1.385 GB, free: 202.1 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003753/2.42, allocations: 104.9 kB / 1.385 GB, free: 202.1 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/Validation/IntegratedPrimaryLoadSide.mo:47:3-49:73:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/Validation/BaseClasses/PartialPlant.mo:65:3-67:73:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: Modelica.Blocks.Sources.BooleanStep onChi(startTime(displayUnit = "h") = 7200) "On and off signal for the chiller" second element is: .Modelica.Blocks.Sources.BooleanStep onChi(startTime = 7200) "On and off signal for the chiller" Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide Error: Internal error SimCode: The model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide could not be translated to FMU