Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620,fileNamePrefix="Buildings_6_0_0_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case620",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 3.894/3.894, allocations: 433 MB / 440.3 MB, free: 4.805 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 0.5529/4.447, allocations: 104.3 MB / 0.5319 GB, free: 13.01 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2561/4.703, allocations: 98.72 MB / 0.6283 GB, free: 9.766 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.23/10.93, allocations: 2.36 GB / 2.988 GB, free: 193.6 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005518/10.93, allocations: 112.9 kB / 2.988 GB, free: 193.5 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620 Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620 could not be translated to FMU