Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate,fileNamePrefix="Buildings_6_0_0_Buildings_Fluid_MixingVolumes_Validation_MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 4.174/4.174, allocations: 433 MB / 440.3 MB, free: 4.828 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 0.5709/4.745, allocations: 104.3 MB / 0.5319 GB, free: 13.02 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.249/4.994, allocations: 98.71 MB / 0.6283 GB, free: 9.84 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.551/10.55, allocations: 2.189 GB / 2.817 GB, free: 159.8 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003174/10.55, allocations: 97.88 kB / 2.817 GB, free: 159.7 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/MixingVolumes/Validation/MixingVolumeTraceSubstanceReverseFlow.mo:10:9-10:18:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource_Xi_C.mo:19:3-22:89:writable] Error: Array dimension mismatch, expression {0.003} has type Real[1], expected array dimensions [0]. Error: Error occurred while flattening model Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate Error: Internal error SimCode: The model Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate could not be translated to FMU