Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection,fileNamePrefix="Buildings_6_0_0_Buildings_Fluid_HeatPumps_Validation_ScrollWaterToWater_TemperatureProtection",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 3.973/3.973, allocations: 433 MB / 440.3 MB, free: 4.824 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 0.5229/4.496, allocations: 104.3 MB / 0.5319 GB, free: 13 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.221/4.717, allocations: 98.72 MB / 0.6283 GB, free: 9.816 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.079/5.796, allocations: 406.5 MB / 1.025 GB, free: 13.68 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003579/5.797, allocations: 94.53 kB / 1.025 GB, free: 13.63 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection Error: Internal error SimCode: The model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection could not be translated to FMU