Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Examples.DualFanDualDuct.ClosedLoop.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Examples.DualFanDualDuct.ClosedLoop,fileNamePrefix="Buildings_6_0_0_Buildings_Examples_DualFanDualDuct_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 3.925/3.925, allocations: 433 MB / 440.3 MB, free: 4.812 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 0.5839/4.509, allocations: 104.3 MB / 0.5319 GB, free: 12.88 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2373/4.746, allocations: 98.74 MB / 0.6283 GB, free: 9.801 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.136/11.88, allocations: 2.734 GB / 3.363 GB, free: 170.5 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003646/11.88, allocations: 93.5 kB / 3.363 GB, free: 170.5 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.Examples.DualFanDualDuct.ClosedLoop Error: Internal error SimCode: The model Buildings.Examples.DualFanDualDuct.ClosedLoop could not be translated to FMU