Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,fileNamePrefix="Buildings_6_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_PumpParallel",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 4.045/4.045, allocations: 433 MB / 440.3 MB, free: 4.84 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 0.5592/4.604, allocations: 104.3 MB / 0.5319 GB, free: 12.55 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2487/4.853, allocations: 98.72 MB / 0.6283 GB, free: 9.715 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.031/5.884, allocations: 431.7 MB / 1.05 GB, free: 5.551 MB / 0.7917 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003528/5.884, allocations: 103.3 kB / 1.05 GB, free: 5.492 MB / 0.7917 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:104:11-104:18:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel Error: Internal error SimCode: The model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel could not be translated to FMU