Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,fileNamePrefix="Buildings_5_0_1_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case650FF",fmuType="me",version="2.0",platforms={"dynamic"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 4.153/4.153, allocations: 404 MB / 410.9 MB, free: 4.934 MB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 0.2603/4.413, allocations: 95 MB / 0.4941 GB, free: 7.344 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5468/4.96, allocations: 92.69 MB / 0.5846 GB, free: 3.41 MB / 474.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 6.638/11.6, allocations: 2.33 GB / 2.915 GB, free: 190.4 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004762/11.6, allocations: 115.2 kB / 2.915 GB, free: 190.3 MB / 0.7761 GB [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getDerTableValue. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableValue. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableTimeTmin. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableTimeTmax. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/HeatTransfer/Data/GlazingSystems.mo:38:5-42:31:writable] Error: Dimensions must be parameter or constant expression (in size(glass, 1)). [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:96:7-96:25:writable] Error: Component roo.datConExtWin[1].glaSys of variability PARAM has binding window600 of higher variability VAR. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF Error: Internal error SimCode: The model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF could not be translated to FMU