OMSimulator --tempDir=temp_Buildings_5_0_1_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu --startTime=0 --stopTime=1000 --timeout=50 --tolerance=1e-08 Buildings_5_0_1_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_5_0_1_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu" info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Buildings_5.0.1_Buildings.Fluid.Movers.Validation.Pump_Nrpm_stratos/temp_Buildings_5_0_1_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Buildings_5.0.1_Buildings.Fluid.Movers.Validation.Pump_Nrpm_stratos" info: New model "model" with corresponding temp directory "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Buildings_5.0.1_Buildings.Fluid.Movers.Validation.Pump_Nrpm_stratos/temp_Buildings_5_0_1_Buildings_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu/model-x1lnyknq" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump2.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump3.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump4.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump5.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. stdout | info | The initialization finished successfully without homotopy method. info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 911 NumRhsEvals = 912 NumLinSolvSetups = 48 NumNonlinSolvIters = 911 NumNonlinSolvConvFails = 0 NumErrTestFails = 0